Accuracy test analysis of TD500A drilling and tapping center based on i5 system
-
摘要: 选择通用技术集团大连机床有限责任公司自主生产的TD500A立式钻攻中心为试验样机,匹配i5智能系统,以其整体为研究对象。通过雷尼绍激光干涉仪对其定位精度、重复定位精度进行测试,进一步验证配置i5系统的TD500A钻攻中心在精度方面的可靠性。研究结果表明:TD500A立式钻攻中心机床中的i5系统经过补偿,在线性轴定位精度等方面上有很大提升,文中研究结论对该系统在机床中的应用具有重要参考价值。
-
关键词:
- TD500A钻攻中心 /
- i5系统 /
- 雷尼绍激光干涉仪 /
- 定位精度 /
- 重复定位精度
Abstract: The TD500A vertical drilling and tapping center independently produced by Dalian Machine Tool Co., Ltd. of general technology group is selected as the experimental prototype, which is matched with i5 intelligent system. The positioning accuracy and repeated positioning accuracy of TD500A drilling and tapping center with i5 system are tested by Renishaw laser interferometer to further verify the reliability of the accuracy. The results show that: the research conclusions have important reference value for the application of the system in machine tools. -
表 1 线性轴线行程至2 000 mm的定位精度的公差
检验项目 轴线的测量行程 ≤500 >500
~800>800
~1000>1250
~2000公差 双向定位精度 A 0.022 0.025 0.032 0.042 单向定位精 A↑和A↓ 0.016 0.020 0.025 0.030 双向重复定位精度 R 0.012 0.015 0.018 0.020 单向重复定位 R↑R↓ 0.006 0.008 0.010 0.013 轴线的反向偏差 B 0.010 0.010 0.012 0.012 轴线的平均反向偏差 $\bar B$ 0.006 0.006 0.008 0.008 双向定位系统偏差 E 0.015 0.018 0.023 0.030 单向定位系统偏差 E↑E↓ 0.010 0.012 0.015 0.018 轴线平均双向位置偏差范围 M 0.010 0.012 0.015 0.020 -
[1] 刘娟. TD500A立式钻攻加工中心的关键结构的设计与改进[D]. 大连: 大连理工大学, 2018. [2] 张曙. 智能制造与i5智能机床[J]. 机械制造与自动化, 2017, 46(1): 1-8 [3] 贾平平. 激光干涉仪原理与应用研究[J]. 山东工业技术, 2018(20): 9,247. [4] 李连军. 数控机床精度故障诊断及维修工艺研究[J]. 现代工业经济和信息化, 2021, 11(5): 145-147. [5] 黄献, 何峰. 数控机床误差补偿技术研究[J]. 内燃机与配件, 2021(8): 90-91. doi: 10.3969/j.issn.1674-957X.2021.08.037 [6] 杨斌, 冉琰, 张根保. 基于元动作模块的多轴数控机床精度分析[J]. 中国机械工程, 2020, 31(13): 1621-1628. [7] 王丽娜, 田文杰, 张大卫. 数控机床几何精度设计指标确定方法研究[J]. 机械工程学报, 2020, 56(1): 166-174.